PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT J, 250A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

MainRangePowerPactproduct namePowerPact JProduct or Component TypeCircuit breakerDevice ApplicationDistribution

ComplementaryLine Rated Current250 ANumber of Poles3PControl TypeToggleBreaking capacity codeGBreaking capacity65 kA 240 V AC 50/60 Hz UL 489
35 kA 480 V AC 50/60 Hz UL 489
18 kA 600 V AC 50/60 Hz UL 489
20 kA 250 V DC UL 489
20 kA 500 V DC UL 489
[Ue] rated operational voltage600 V AC 50/60 Hz IEC 60947-3Network Frequency50/60 Hz[Ics] rated service breaking capacity65 kA 220/240 V AC 50/60 Hz IEC 60947-2
35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2
18 kA 500/525 V AC 50/60 Hz IEC 60947-2
20 kA 250 V DC IEC 60947-2
20 kA 500 V DC IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2Trip unit technologyThermal-magneticMagnetic tripping current2500 AMagnetic hold current1250 AContinuous current rating80 %[Ui] rated insulation voltage750 V IEC 60947-2Protection TypeOverload protection
Short-circuit protection
Suitability for isolationYes IEC 60947-2Utilisation categoryCategory AAWG gaugeAWG 3/0...350 kcmil aluminium/copper terminalsLocal signallingSwitched off (OFF) 1 trip indicator green)Mounting modeUnit mount busbar)Mounting SupportBusbarElectrical connectionBusbar connection, line
Busbar connection, load
Terminal identifierAL250JDLong time pick-up adjustment range0.25...1 x InTightening torque221.3 lbf.in (25 N.m) 0.1…0.3 in² (95…185 mm²) (AWG 3/0...350 kcmil)Number of slots2 auxiliary switch OF plug-in)
1 alarm switch SD plug-in)
1 overcurrent trip switch SDE plug-in)
1 voltage release MN or MX plug-in)
Power wire stripping length1.0 in (25 mm)Height7.5 in (191 mm)Width4.09 in (104 mm)Depth3.4 in (86 mm)Net Weight5.3 lb(US) (2.4 kg)Communication interfaceModbus
Ethernet
Circuit breaker applicationHACR rated

EnvironmentQuality labelsCEStandardsUL
CSA
NEMA
NOM-003-SCFI-2000
IEC 60947-2
Product certificationsUL
CSA
NOM
IP degree of protectionFront cover IP40Pollution degree3 IEC 60947-1ambient air temperature for operation-13…158 °F (-25…70 °C)Ambient Air Temperature for Storage-58…185 °F (-50…85 °C)Operating altitude< 6561.68 ft (2000 m) without derating
5000 m with derating

Ordering and shipping detailsCategoryUS10DE201115Discount Schedule0DE2GTIN785901635888ReturnabilityNoCountry of originMX

Packing UnitsUnit Type of Package 1PCENumber of Units in Package 11Package 1 Height5.13 in (13.018 cm)Package 1 Width7.25 in (18.415 cm)Package 1 Length8.44 in (21.433 cm)Package 1 Weight3.68 lb(US) (1.67 kg)

MSRP:$5001.00 before Taxes. in Stock! 

Get it at a very large discount!

Description

PowerPacT J-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT J-Frame circuit breakers are available with either thermal magnetic or MicroLogic electronic trip protection units. This PowerPacT J-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT J-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT J circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has a busbar connection. This PowerPacT J, 250A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT J circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.

Specifications

MainRangePowerPactproduct namePowerPact JProduct or Component TypeCircuit breakerDevice ApplicationDistribution

ComplementaryLine Rated Current250 ANumber of Poles3PControl TypeToggleBreaking capacity codeGBreaking capacity65 kA 240 V AC 50/60 Hz UL 489
35 kA 480 V AC 50/60 Hz UL 489
18 kA 600 V AC 50/60 Hz UL 489
20 kA 250 V DC UL 489
20 kA 500 V DC UL 489
[Ue] rated operational voltage600 V AC 50/60 Hz IEC 60947-3Network Frequency50/60 Hz[Ics] rated service breaking capacity65 kA 220/240 V AC 50/60 Hz IEC 60947-2
35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2
18 kA 500/525 V AC 50/60 Hz IEC 60947-2
20 kA 250 V DC IEC 60947-2
20 kA 500 V DC IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2Trip unit technologyThermal-magneticMagnetic tripping current2500 AMagnetic hold current1250 AContinuous current rating80 %[Ui] rated insulation voltage750 V IEC 60947-2Protection TypeOverload protection
Short-circuit protection
Suitability for isolationYes IEC 60947-2Utilisation categoryCategory AAWG gaugeAWG 3/0...350 kcmil aluminium/copper terminalsLocal signallingSwitched off (OFF) 1 trip indicator green)Mounting modeUnit mount busbar)Mounting SupportBusbarElectrical connectionBusbar connection, line
Busbar connection, load
Terminal identifierAL250JDLong time pick-up adjustment range0.25...1 x InTightening torque221.3 lbf.in (25 N.m) 0.1…0.3 in² (95…185 mm²) (AWG 3/0...350 kcmil)Number of slots2 auxiliary switch OF plug-in)
1 alarm switch SD plug-in)
1 overcurrent trip switch SDE plug-in)
1 voltage release MN or MX plug-in)
Power wire stripping length1.0 in (25 mm)Height7.5 in (191 mm)Width4.09 in (104 mm)Depth3.4 in (86 mm)Net Weight5.3 lb(US) (2.4 kg)Communication interfaceModbus
Ethernet
Circuit breaker applicationHACR rated

EnvironmentQuality labelsCEStandardsUL
CSA
NEMA
NOM-003-SCFI-2000
IEC 60947-2
Product certificationsUL
CSA
NOM
IP degree of protectionFront cover IP40Pollution degree3 IEC 60947-1ambient air temperature for operation-13…158 °F (-25…70 °C)Ambient Air Temperature for Storage-58…185 °F (-50…85 °C)Operating altitude< 6561.68 ft (2000 m) without derating
5000 m with derating

Ordering and shipping detailsCategoryUS10DE201115Discount Schedule0DE2GTIN785901635888ReturnabilityNoCountry of originMX